Glass body dual pH electrode with ATC probe, intensive use

For general laboratory uses and measurements that require greater precision in liquids and non-aqueous solutions, aggressive samples. Resists poisoning and fouling. Reference element Ag/AgCI, non refillable electrolyte and porous teflon diaphragm. pH range 0 - 14, maximum service temperature 130 °C. Dimensions: 120 x 12 mm. Available with BNC connection and 1 m cable, and two types of ATC probe connections: 10K/3.5mm Jack for METRIA meters and 30K/CINCH for XS and Mettler-Toledo

More info

Conductivity electrodes

Conductivity electrodes with temperature compensation to be used with COMT-M51-001 or COMT-M52-001. Dimensions 120 x 12 mm, BNC conection with 1 m cable length. K = 1: conductivity values (0 - 150 mS/cm), temperature range (0 - 100°C). General purpose, plate material: platinum K = 10: conductivity values (0 - 500 mS/cm), temperature range (0 - 100°C). For high conductivity solutions, plate material: carbon K = 0,1: conductivity values (0 - 500 µS/cm), temperature range (0 - 50°C). For pure water, plate material: platinum

More info

Epoxy body pH electrode, dificult samples

Specially designed for measuring difficult samples: dairy products, viscose samples, creams, surface measurements (paper, Agar, skin, ...). Reference element Ag/AgCI, partial gel refillable electrolyte (3.5M KCl/AgCl) and teflon diaphragm. pH range 0 ... 14, maximum service temperature 80 ºC. Dimensions: 120 x 12 mmAvailable with two types of connections: BNC connector with fixed cable (length: 1 m) or S7 connector (delivery without connecting cable, please order separately)

More info

Epoxy body pH electrode for educational use, Basic Line

Specially designed for educational market, combining quality at an affordable price. Minimum maintenance, less frequent calibrations and greater stability. Plastic body (epoxy). Reference element Ag/AgCI, gel non refillable electrolyte and fiber diaphragm. pH range 0 ... 14, maximum service temperature 60 ºC. Dimensions: 120 x 12 mm. Fixed cable 1 m long with BNC connector

More info

Epoxy body pH electrode, general use

Plastic body (epoxy), specially designed for general use in portable pH meters. Reference element Ag/AgCI, gel non refillable electrolyte and porous teflon diaphragm. pH range 0 ... 14, maximum service temperature 80 ºC. Dimensions: 120 x 12 mm. Available with two types of connections: BNC connector with fixed cable (length: 1 m) or S7 connector (delivery without connecting cable, please order separately)

More info

Epoxy body pH electrode, intensive use

Plastic body (epoxy), specially designed for general use in portable pH meters and also for industrial uses. Reference element Ag/AgCI, gel non refillable electrolyte and double porous teflon diaphragm. pH range 0 ... 14, maximum service temperature 80 ºC. Dimensiones: 120 x 12 mm. Available with two types of connections: BNC connector with fixed cable (lenght: 1 m) or S7 connector (delivery without connecting cable, please order separately)

More info

Glass body pH electrode, semi micro applications

Glass body electrode, specially designed for measuring pH in very small sample volumes or narrow vessels. Reference element Ag/AgCI, liquid refillable electrolyte (3M KCl/AgCl) and frit ceramic diaphragm. pH range 0 ... 14, maximum service temperature 80 ºC. Stem dimensions: 90 x 4,5 mm. Available with two types of connections: BNC connector with fixed cable (length: 1 m) or S7 connector (delivery without connecting cable, please order separately)

More info

Glass body pH electrode, for slurries and soil measurements

Glass body electrode, specially designed for measuring pH in slurries and soil. Reference element Ag/AgCI, liquid refillable electrolyte (3M KCl/AgCl) and frit ceramic diaphragm. pH range 0 - 14, maximum service temperature 80 ºC. Dimensions: 12 x 120 mm. BNC connector with fixed cable (length: 1 m) or S7 connector (delivery without connecting cable, to be ordered separately)

More info

Glass body pH electrode for high temperature measurements

Specially designed for high temperature measurements and for industrial pipeline. Reference element Ag/AgCI, gel non refillable electrolyte and double teflon diaphragm. pH range 0 ... 14, maximum service temperature 130 ºC. Dimensions: 120 x 12 mm. Fixed cable 1 m long with BNC connector

More info

Glass body pH electrode, for liquids

Glass body electrode, specially designed for measuring pH in liquids and deep flasks with narrow neck. Reference element Ag/AgCI, liquid refillable electrolyte (3M KCl/AgCl) and frit ceramic diaphragm. pH range 0 - 14, maximum service temperature 80 ºC. Lower shaft dimensions: 150 (±2mm) x 6,2 mm (±2mm). BNC connector with fixed cable (length: 1 m) or S7 connector (delivery without connecting cable, to be ordered separately)

More info

Glass body pH electrode, general use

For general use. Aqueous solutions. Reference element Ag/AgCI, liquid refillable electrolyte (3M KCl/AgCl) and annular ceramic diaphragm. pH range 0 ... 14, maximum service temperature 80 ºC. Dimensions: 120 x 12 mm. Available with two types of connections: BNC connector with fixed cable (lenght: 1 m) or S7 connector (delivery without connecting cable, please order separately)

More info

Glass body pH electrode, intensive use

For general use and high accuracy measurements in liquids and non aqueous samples. Reference element Ag/AgCI, liquid refillable electrolyte (3M KCl/AgCl) and double ceramic diaphragm. pH range 0 ... 14, maximum service temperature 80 ºC. Dimensions: 120 x 12 mm. Available with two types of connections: BNC connector with fixed cable (length: 1 m) or S7 connector (delivery without connecting cable, please order separately)

More info