Labels for cryogenic storage purposes. Round shape. Withstand extreme cold temperatures from -196º C – 121º C. Special material engineered to expand and contract with dramatic temperature changes. Permanent adhesive. Available in rolls in various sizes of one colour or assorted. Can be written on with a pen, pencil, or permanent marker without smearing
More info
L'étuve sous vide avec un large volume de 264 litres comprend un contrôleur de température Watlow qui peut être programmé pour effectuer plusieurs profils de rampe et de trempage.
More info
Pour le séchage en douceur des bactéries et des cultures de démarrage ou la simulation de vols intercontinentaux.
More info
A range of drying ovens either with natural convection (SLN) or with forced air circulation (SLW).
More info
Les étuves de Laboratoire Haute Température série LHT, comprennent 3 tailles d'étuves de paillasse, chacune disponible avec des températures max d'opération de 400°C, 500°C et 600°C. Ces étuves offrent de hautes températures qui sont plus typiques des étuves industrielles dans une conception compacte qui peut aller sur une paillasse.
More info
Les étuves pour chauffage de couvertures sont particulièrement indispensables pour les soins des blessés graves, en particulier dans la salle de réanimation des urgences, mais elles rendent également de grands services chaque jour en salle d’accouchement ou de réveil. Les couvertures et chiffons préchauffés précisément dans une étuve IFbw sont immédiatement accessibles afin d’envelopper les patients chaudement et de réduire le risque de complications tels que l’infection des plaies, les troubles cardiovasculaires, les troubles du rythme cardiaque ou les problèmes de circulation.
More info
Set of vertical glassware included (REVA-A01-001). Speed range from 20 to 280 rpm. Large 5 L water-oil heating bath with heating temperature range of RT to 180 ºC, with precise temperature control (±1ºC in water) and adjustable safety circuit. Large and easy to read digital LCD screen displays heating temperature, rotation speed and timing. Patented condenser with excellent cooling effect (cooling surface 1700 cm2). Motorized lift with quick-action, automatic release of evaporating flask to top position in case of power failure. Adjustable final position recognition to protect operator and sample against breakage. Evaporating flask with an ejector, easy to remove. Chemically resistant double PTFE system and patented pressure spring provide excellent sealing. External dimensions (mm): 583x465x457. Weight (Kg): 15. PC can control and document all parameters via RS232 interface (USB). 100-240 V / 50-60 Hz, insulation rating IP20 (DIN EN60529). Warranty 2 years. It is recommended to combine with the vacuum pump VACU-R20-001. The most suitable rubber tubing references are RUTT-006-002 for the vacuum and LTXT-007-005 for the condenser
More info
Set of vertical glassware included (REVA-A01-001). Speed range from 20 to 200 rpm. 5 L water-oil heating universal bath with heating temperature range of RT to 180 °C, with a precise temperature control (±1ºC in water) and that can be used independently.LED screen that displays heating temperature, rotation speed and timing. Patented condenser with excellent cooling effect (cooling surface 1700 cm2). Manual lift combined with auxiliary lift for precise positioning of the glassware. Evaporating flask with an ejector, easy to remove. Chemical-resistant double PTFE system and patented pressure spring provide excellent sealing. External dimensions (mm): 440 x 320 x 450 (main unit) and 300 x 300 x 240 (heating bath). Weight: 7 kg (main unit) and 3 kg (heating bath). 100-240 V / 50-60 Hz, insulation rating IP20 (DIN EN60529). Warranty 2 years.It is recommended to combine with the vacuum pump VACU-R20-001. The most suitable rubber tubing references are RUTT-006-002 for the vacuum and LTXT-007-005 for the condenser
More info
To be placed between the surface of the sample and the lens of the microscope to eliminate the deflection of the beam of light and improve the effectiveness of the lens considerably. Refractive index (nD) at 25°C between 1.472 and 1.480 and viscosity at 40°C between 99 and 120 cSt
More info
Benchtop pH/ORP meter with automatic or manual temperature compensation (between 0 and 100 ° C). Range: -1.00 - 15.00 pH, resolution: 0.01 pH, accuracy ± 0.01 pH. Redox range: ± 1999 mV, accuracy ± 1 mV. Standard BNC connector for pH or redox electrodes and Phone Plug (3.5 mm) for the ATC probe. Autocalibration in 3 points according to USA (pH 4.01, 7.00 and 10.01) or NIST (pH 4.01, 6.86 and 9.18). Backlit LCD screen. Auto-Hold feature senses and locks the measurement endpoint. Automatic electrode slope display helps user decide chether to replace the sensor. Includes buffer solutions (pH 4.01, 7.00 and 10.01), electrode holder, METRIA electrode PHEL-GB1-001 (maximum service temperature 80 ºC) and CAT probe. Warranty 2 years. Stirrer STIS-000-001 recommended
More info
Benchtop pH/ORP meter with automatic or manual temperature compensation (between 0 and 100 ° C). Range: -2.000 - 20.000 pH, resolution: 0.001 pH, precision ± 0.002 pH. ORP range: ± 1999 mV, resolution ± 0.2 mV. Standard BNC connector for pH or redox electrodes and Phone Plug (3.5 mm) for the ATC probe. Auto-calibration from 1 to 5 points according to USA, NIST, DIN or customized and recalibration alarm from 1 to 31 days. Backlit LCD screen. Stability indicator that recognizes the measurement as stable and expanded memory with a capacity of 500 readings. Includes buffer solutions (pH 4.01, 7.00 and 10.01), electrode holder, METRIA PHEL-GB1-001 electrode (maximum service temperature 80 ºC), CAT probe and USB cable. Warranty 2 years. STIS-000-001 stirrer recommended
More info
Desktop pH meter with automatic and manual temperature compensation (between 0 and 80 ºC). pH range: 0 - 14 pH, resolution: 0.01 pH, accuracy ± 0.02 pH. Redox range: ± 1000 mV, resolution ± 1 mV. Standard BNC connector for pH and redox electrodes. Automatic calibration in 3 points (pH 4.01, 7.00 and 10.01). Backlit LCD display. Keypad resistant to water, bases and acids splashes. Stable measurement indication. Includes buffer solutions (pH 4.01 and 7.00), electrode arm, electrode for general use with BNC fixed cable and integrated CAT probe. Plastic body electrode, with gel electrolyte, pH range 0 - 14 and 0 - 60 ºC. Warranty 3 years. Delivery 1 week
More info