Vertical autoclaves Type LVSA

The Laboratory- Vertical- Standing- Autoclaves, short LVSA, are characterized by their low loading height and easy operation. Our autoclaves are available in four different sizes: Vertical autoclaves with a chamber volume of 80, 96, 133 and 153 litres
More informations

Share

The range

LVSA 40/60

Chamber Vol. (L)

80

Diam. int. (Ø x H)

400 x 620 mm

Power (W)

6000

Loading height

760

Dimensions (mm)

550 x 850

Technical sheet

LVSA 40/75

Chamber Vol. (L)

96

Diam. int. (Ø x H)

400 x 770 mm

Power (W)

6000

Loading height

900

Dimensions (mm)

550 x 850

Technical sheet

LVSA 50/60

Chamber Vol. (L)

133

Diam. int. (Ø x H)

500 x 680 mm

Power (W)

9000

Loading height

800

Dimensions (mm)

700 x 950

Technical sheet

LVSA 50/70

Chamber Vol. (L)

153

Diam. int. (Ø x H)

500 x 780 mm

Power (W)

9000

Loading height

900

Dimensions (mm)

700 x 950

Technical sheet

  • German manufacturing

  • All stainless steel for greater durability and easy cleaning

  • Ergonomic loading height of 750mm

  • Water-saving rapid cooling

  • Electric arm for easy loading and unloading

  • 7 versions and many options to meet your needs

  • In particular GMP versions

  • Qualification IQ,OQ,PQ

  • Spare parts are available for 10 years

  • You can configure your LVSA autoclave on this link

The autoclave is equipped with a fully automatic vertical door.

Low maintenance.
Maximum security.
Saving space in your lab

Ecran tactile 10"

Ecran tactile 10"

The 7" touch screen allows control of the autoclave from the front panel.

This screen contains a PC which communicates control information to the PLC. The software is very comprehensive and easy to use. The data from each batch is stored in the autoclave and can either be printed or sent via the Ethernet port to a PC in .pdf or .csv format for archiving and/or analysis.

Steam generator

Steam generator

All LVSA models are equipped with a compact steam generator integrated into the autoclave body. It works with demineralized water to avoid the formation of non-condensable gases in the chamber.

Internal brewing fan - rapid cooling

To shorten the cooling time, this fan circulates the air inside the chamber to bring it into contact with the walls which are cooled by the double mantle.

This option saves cooling water and ensures much better homogeneity in the chamber. Essential to avoid overflows (AGAR in particular).

LVSA 50/70 avec bras de levage

LVSA 50/70 avec bras de levage

Electric lifting arm

This lifting arm can lift up to 23kgs. It will save you a lot of back pain and tendinitis during the 20 years of operation of your autoclave.

Flexible probe for liquid cycles

The LVSAs are all equipped with a flexible probe for liquid programs (and probe calibration).

High-performance liquid ring vacuum pump

A liquid ring vacuum pump allows you to completely remove the air contained in your products and replace them with sterilizing steam. You can choose between these "pre-vacuums" in one step (for liquids and glassware) or with successive pre-vacuums configurable by the user (for waste and instruments).

Front thermal printer

A thermal printer can be added as an option on the front panel.

  1. BASIC LAB version: recommended for simple needs. Sterilization of liquids or solids without drying. Equipment: steam generator and automaton with SteriTouch Control software

  2. DRY LAB version: recommended for the sterilization of solids (waste, instruments) with imperative drying. Equipment: steam generator, automaton with SteriTouch Control software, vacuum pump

  3. QUICK LAB BASIC version: recommended for sterilizing liquids with rapid cooling. Equipment: steam generator, automaton with SteriTouch Control software, cooling with internal mixing fan.

  4. QUICK LAB version: recommended for the sterilization of non-infectious solids (waste, instruments) and liquids with imperative drying and rapid cooling. Equipment: steam generator, automaton with SteriTouch Control software, vacuum pump, internal mixing fan

  5. QUICK LAB ADVANCED version: recommended for the sterilization of non-infectious solids (waste, instruments) and liquids with imperative drying and rapid cooling. Suitable for agars and liquids in closed containers to avoid spillage during cooling. Equipment: steam generator, automaton with SteriTouch Control software, vacuum pump, internal mixing fan, back pressure with air-steam mixture

  6. SAFE LAB version: recommended for the sterilization of INFECTIOUS solids (waste, instruments) of type S2, with imperative drying. Equipment: steam generator, automaton with SteriTouch Control software, vacuum pump, ALF filter on the air outlet

  7. COMPLETE LAB version: recommended for the sterilization of solids (waste, instruments) and INFECTIOUS liquids of type S2, with imperative drying and rapid cooling. Equipment: steam generator, automaton with SteriTouch Control software, vacuum pump, internal circulation fan", ALF filter on the air outlet

  1. Stainless steel sterilisation baskets, pails and containers

  2. Front thermal printer

  3. Lifting and pivoting mechanism Vidéo -->

  4. Validation DQ,FAT,IQ,OQ,PQ,SAT Qualification