ICH / ICHL climate chambers

Excellent homogeneity both in terms of temperature and humidity! Climatic chamber for stability tests according to ICH, WHO, AEM, ASEAN, GMP, GLP, BPCC guidelines.
More informations

Share

The range

ICH110

Int. dim ( W x H x D ) mm

560x480x400 mm

Temperature

-10 à +60 °C

Humidité

10 à 80%

Capacity

108

Lumière

Non

Technical sheet

ICH110L

Int. dim ( W x H x D ) mm

560x480x400 mm

Temperature

+10 à +60°C

Humidité

10 à 80%

Capacity

108

Lumière

Oui

Technical sheet

ICH260

Int. dim ( W x H x D ) mm

824x1552x685 mm

Temperature

-10 à +60°C

Humidité

10 à 80%

Capacity

254

Lumière

Non

Technical sheet

ICH260L

Int. dim ( W x H x D ) mm

824x1552x685 mm

Temperature

+10 à +60°C

Humidité

10 à 80%

Capacity

254

Lumière

Oui

Technical sheet

ICH750

Int. dim ( W x H x D ) mm

1224x1950x785 mm

Temperature

-10 à +60°C

Humidité

10 à 80%

Capacity

749

Lumière

Non

Technical sheet

ICH750L

Int. dim ( W x H x D ) mm

1224x1950x785 mm

Temperature

+10 à +60°C

Humidité

10 à 80%

Capacity

749

Lumière

Oui

Technical sheet

  • User-friendly and intuitive to use

  • Programming temperature/humidity ramps using AtmoCONTROL software

  • Inner casing and outer wall made almost exclusively from high-quality, corrosion-resistant and easy-to-maintain stainless steel.

  • Heating concept specifically tailored to the product for precise and consistent thermal control

  • Extensive programming and documentation options using interfaces, built-in state logging and AtmoCONTROL software

  • 3 years warranty (worldwide)

  • Temperature limitation, temperature: +60 °C (A8)

  • Interior box modification for use of reinforced perforated stainless steel trays or reinforced stainless steel grids (support slides mounted in the box) - includes delivery of reinforced grids to replace standard grids (standard for 1060 models) (K1)

  • 6,500 K cool-white lighting module, LED strips fixed against side walls, 10 on mod. 110, 14 on mod. 260/410/750, (programmable attenuation from 0 – 100% in 1% steps). Programming of ramps, depending on temperature and humidity; do not use in combination with F6 (T7)

  • Cool white 6,500 K, warm white 2,700 K lighting module, LED strips, 10 models 110, 14 models 260/410/750, alternating 5 or 7 cool white and 5 or 7 warm white, fixed to side walls ; (programmable attenuation from 0 – 100% in steps of 1%). Programming of ramps based on temperature and humidity; do not use in combination with F6 (T8)

  • 2,700 K warm-white lighting module, LED strips fixed against side walls, 10 on mod. 110, 14 on mod. 260/410/750, programmable attenuation from 0 – 100% in 1% steps. Programming of ramps, depending on temperature and humidity; do not use in combination with F6 (T9)

  • Indoor socket (only available for restricted temperature range up to +60°C maximum), permissible load 230V/2.2A/500W, switching by main switch, no separate switch, moisture-proof IP68 (requires option A8 against overload) (R3)

  • Passage of 23 mm internal diameter for the lateral introduction of cables, moisture-tight, closable by flap and silicone plug, standard positioning on the left - middle/middle (F0)

  • Passage (silicone), internal diameter. 40 mm, moisture-proof, sealed with silicone plug; on rear wall, positions to be specified (F7)

  • Current interface 4 to 20 mA (temperature range -10 to +80°C equivalent to 4 to 20 mA), actual value of temperature controller (V3)

  • Compressed air drying (powerful dehumidification of the interior box by introducing compressed air). Standard factory calibration certificate (measuring point in the center of the usable space) for +10°C with 10% rh (C9)

  • Keyed safety lock (safety lock) (B6)

  • Potential-free contact (24 V/2 A) with socket for displaying error messages (ALARM in case of power failure, sensor malfunction, fuse problem) (H6)

  • Programmable process-dependent door locking (only on TwinDISPLAY devices) (D4)

  • Warning in case of open door (only on TwinDISPLAY devices) (V5)

  • MobileALERT, sending an SMS in the event of a malfunction or triggering of the device alarm (Option H6 required) (C3)

  • MobileALERT for sending 2 alarm messages; transmission of an SMS message. alarm for temperature and humidity (Option H6 required) (C4)

  • Stainless steel grid, electropolished

  • Reinforced stainless steel grid, electropolished, admissible load up to 60 kg (model 750 with guide rail and fixing screws, usable only with option K1) Observe the max. load. of the device

  • Perforated stainless steel tray

  • Reinforced perforated stainless steel platform, load capacity up to 60 kg, with guide rail and fixing screws, can only be used with option K1

  • Built-in stainless steel drip tray, 15 mm edge (likely to disrupt the distribution of ambient temperature), cannot be used with option K1

  • Non-perforated stainless steel tray, rim height of 15 mm, with guide rail and fixing screw (likely to disrupt temperature uniformity) – usable only with option K1

  • Central water supply with filter cartridges for connection to the drinking water network. Product information on request

  • Central water supply without filter cartridges for connection to the drinking water network (the device only uses demineralized/totally desalinated water with a conductivity of 5 to 10 μS/cm and a pH between 5 and 7) . Product information on request

  • USB-Ethernet adapter

  • 5m Ethernet cable for connection to computer

  • USB stick with user ID (user ID): User license on USB stick for a defined device to prevent unauthorized intervention by third parties. Device number to be specified for any subsequent order (only for TwinDISPLAY devices).

  • FDA-compliant software “AtmoCONTROL FDA-Edition”. Meets the requirements for the use of electronic data blocks in memory and for electronic signatures, defined in the Guidelines 21 CFR part 11 of the US Food and Drug Administration (FDA). Basic license for controlling a device (compatible with TwinDISPLAY devices only). IQ/OQ document available in German and English (without surcharge)