Rapid and energy-efficient temperature variation in the climatic chamber
Fast, precise and energy-efficient temperature variation between -42°C and +190°C, as well as relatively short hygrometric recovery times, make the TTC thermal test chamber and climatic test chamber CTC with hygrometric unit a perfect duo for controlled materials testing, functional testing, aging testing or even climatic testing of composites, concrete, plastic or electronic components used in the areas of materials technology, automotive, aeronautics, aerospace and electronics.
Temperature range -42°C to +190°C
1 model size (256 liters internal volume)
Control technology proven for many years
Electronically controlled active humidification and dehumidification from 10% to 98% relative humidity
Design perfectly suited to testing in accordance with IEC 60068
High-tech insulation system for long-lasting insulation power and energy efficiency
Kinetics of temperature changes in heating mode according to IEC 60068-3-5: 10 K/min (from -40 °C to +180 °C; measured at an ambient temperature of 22 °C)
Kinetics of temperature changes in refrigeration mode according to IEC 60068-3-5: 3 K/min. (from +180°C to -40°C; measured at an ambient temperature of 22°C)
R449A refrigerant
Model | Dim. ext. (L x H x D) | Temperature | Humidité | Capacity | Technical sheet | Price | Cart |
---|---|---|---|---|---|---|---|
CTC256 | 898x1730x1100 mm | -42°C à +190°C | 10% à 98% | 256 |
|
|
|
TTC256 | 898x1730x1100 mm | -42°C à +190°C | na | 256 |
|
|
|
Dim. ext. (L x H x D)
Temperature
Humidité
Capacity
Technical sheet
Dim. ext. (L x H x D)
Temperature
Humidité
Capacity
Technical sheet
Heating concept specifically adapted to the product for precise and homogeneous thermal control
Perfect environment simulation for climatic and thermal testing
Extensive programming and documentation options using interfaces, “Celsius” software, integrated recording of status memories and smart cards
Guaranteed safety for the loading element thanks to alarm functions, triple overtemperature protection and simultaneous display of all parameters
Inner casing and outer wall made almost exclusively from high quality stainless steel, corrosion resistant and easy to maintain
3 years warranty (worldwide)
R449A refrigerant significantly more environmentally friendly than R404A
Transparent glass door (5-layer insulating glass), heated (B0)
Passage, left, 80 mm, with blanking plug (F0)
Opening the door on the left (B8)
Potential-free contact (24 V/2 A) with socket conforming to the NAMUR NE 28 standard for displaying error messages specific to the mixture (ALARM for power failure, sensor malfunction, fuse, for example); VO only in combination with option T5 (H6)
Ethernet interface rather than USB, with software (W4)
RS232 interface rather than USB (W6)
MobileALERT, sending an SMS in the event of a malfunction or triggering of the device alarm (Option H6 required) (C3)
Stainless steel grid, electropolished
FDA compliant software “Celsius FDA-Edition”. Meets the requirements for the use of electronic data blocks in memory and for electronic signatures, defined in the US Food and Drug Administration (FDA) Guidelines 21 CFR part 11. Basic license for controlling a device
Integration of additional devices (15 maximum) into a pre-existing FDA license
External control and status recording kit, consisting of mini-laptop and pre-configured “Celsius” software, with side swivel arm
USB cable for connection to computer
Additional blank, pre-formatted smart card (32 KB MEMoryCard XL for 40 ramps maximum)
Coded access card for a specific device (User-ID-Card) to prevent manipulation by unauthorized third parties. Device number to be specified for any subsequent order.
Device for reading/writing temperature profiles for programming purposes from a PC, as well as writing and reading from a smart card (40 ramps maximum)
External measuring device with daylight and UV probes and measuring head for temperature and humidity. Product information on request (HCP and CTC models)
Calibration in the Memmert factory for one or more freely selectable temperature and humidity values
DQ/IQ/OQ/PQ qualification